Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Function | Voltage - Supply | Trip Range | Delay Time | Mounting Type | Termination Style | Features | Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SE-701-0U-CCSE-701-0U WITH CONFORMAL COATING Littelfuse Inc. |
0 |
|
![]() Datasheet |
- | Bulk | Active | Ground Fault | 120 ~ 240VAC/DC | - | 0.05 ~ 2.5s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-704-0U-CCSE-704-0U WITH CONFORMAL COATING Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-704 | Bulk | Active | Ground Fault | 120/240VAC/DC | 0.01 ~ 5A | 0.03 ~ 2s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-704-03-CCSE-704-03 WITH CONFORMAL COATING Littelfuse Inc. |
0 |
|
![]() Datasheet |
- | Bulk | Active | Ground Fault | 24VAC | 0.01 ~ 5A | 0.03 ~ 20s | DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-105EGF-GC MON C/W 1N5339B TERM 240VA Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-105 | Bulk | Active | Ground Fault | 240VAC | 0.5 ~ 4A | 0.1 ~ 1s | Chassis Mount | Screw Terminal | Automatic Reset, Manual Reset | -40°C ~ 60°C |
![]() |
SE-107EGF-GC MONITOR UVR 240 VAC SUPPLY Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-107 | Bulk | Active | Ground Fault | 240VAC | 0.5 ~ 4A | 0.1 ~ 1s | Chassis Mount | Screw Terminal | Automatic Reset, Manual Reset | -40°C ~ 60°C |
![]() |
SE-701-0TGROUND FAULT RELAY 32-70 VDC SUP Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-701 | Bulk | Active | Ground Fault | 48VDC | - | 0.05 ~ 2.5s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
SE-MUXGF/GC TERM MULTIPLEXER Littelfuse Inc. |
0 |
|
- |
* | Bulk | Obsolete | - | - | - | - | - | - | - | - |
![]() |
SE-701-0D-CCSE-701-0D WITH CONFORMAL COATING Littelfuse Inc. |
0 |
|
![]() Datasheet |
- | Bulk | Active | Ground Fault | 12 ~ 24VDC | - | 0.05 ~ 2.5s | Chassis Mount, DIN Rail | Screw Terminal | CT Loop Monitoring, Harmonic Filtering, Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
D0100.0010ARC DETECTING RELAY 48-220VDC Littelfuse Inc. |
0 |
|
![]() Datasheet |
D0100 | Bulk | Discontinued at Digi-Key | Arc-Flash | 48 ~ 220VDC | 2 ~ 24 klux | - | DIN Rail | Screw Terminal | - | -25°C ~ 70°C |
![]() |
D0100.0020JUNCTION WO. INDICATION Littelfuse Inc. |
0 |
|
![]() Datasheet |
D0100 | Bulk | Discontinued at Digi-Key | Arc-Flash | 24VDC | 2 ~ 24 klux | - | DIN Rail | Screw Terminal | - | -25°C ~ 70°C |