Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Function | Voltage - Supply | Trip Range | Delay Time | Mounting Type | Termination Style | Features | Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
SE-325ETNGR MON 240 VAC GF TIME 0.1-5S Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-325 | Bulk | Active | Ground Fault, Overvoltage | 240VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
![]() |
SE-325NNGR MONITOR 120 VAC NON-LATCHING Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
![]() |
SE-325PNGR MON 120 VAC 4K8 NGR SHORT DE Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
![]() |
SE-325SNGR MONITOR EXT RES TRIP TIME Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
![]() |
SE-325TNGR MONITOR 120 VAC GF TIME 0.1- Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-325 | Bulk | Active | Ground Fault, Overvoltage | 120VAC | 0.5 ~ 4A | 0.1 ~ 2s | Chassis Mount | Screw Terminal | Manual Reset | -40°C ~ 60°C |
![]() |
SE-105DGF-GC MONITOR 120-VAC/DC Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-105 | Bulk | Active | Ground Fault | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 1s | Chassis Mount | Screw Terminal | Automatic Reset, Manual Reset | -40°C ~ 60°C |
![]() |
SE-107DGF-GC MONITOR UVR 120 VAC/VDC SU Littelfuse Inc. |
0 |
|
![]() Datasheet |
SE-107 | Bulk | Active | Ground Fault | 120VAC/DC | 0.5 ~ 4A | 0.1 ~ 1s | Chassis Mount | Screw Terminal | Automatic Reset, Manual Reset | -40°C ~ 60°C |
![]() |
SE-601-0T-CCSE-601-0T WITH CONFORMAL COATING Littelfuse Inc. |
0 |
|
![]() Datasheet |
- | Bulk | Active | Ground Fault, Overcurrent | 48VDC | 1 ~ 20mA | 0.05 ~ 2.5s | Chassis Mount, DIN Rail | Screw Terminal | Manual Reset, Test Button | -40°C ~ 60°C |
![]() |
AF0100-00-CCARC-FLASH RELAY UNIV W/CONFORMAL Littelfuse Inc. |
0 |
|
![]() Datasheet |
AF0100 | Bulk | Active | Arc-Flash | 100 ~ 240VAC/DC, 24 ~ 48VDC | 10 ~ 25 klux | - | Chassis Mount, DIN Rail | Screw Terminal | - | -40°C ~ 70°C |
![]() |
AF0100-10-CCARC-FLASH RELAY 24V W/CONFORMAL Littelfuse Inc. |
0 |
|
![]() Datasheet |
AF0100 | Bulk | Active | Arc-Flash | 24 ~ 48VDC | 10 ~ 25 klux | - | Chassis Mount, DIN Rail | Screw Terminal | - | -40°C ~ 70°C |