Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
LF 2005-S/SP30TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
CTD00000SENSOR CURRENT 50A, 75A, 100A |
0 |
|
![]() Datasheet |
- | Module, Single Pass Through | Bulk | Active | DC | Hall Effect, Open Loop | 50A, 75A, 100A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | DC | ±0.75% | ±1% | 24V | 100ms | 84mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
2814634SENSOR CURRENT HALL 11A AC/DC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 11A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
![]() |
CRD5170-XXX-XX-MCRD5170-XXX-XX-M |
0 |
|
![]() Datasheet |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LT 100-T/SP95TRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
ISOBLOCK I-ST-1C (60A 10V)TRANSDUCER CURRENT 9-28VDC |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 60A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (60A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 60A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
LF 2005-S/SP9TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | - | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
DV 2800/SP1TRANSDUCER |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
ISOBLOCK I-ST-1C (70A 10V)TRANSDUCER CURRENT 9-28VDC |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 70A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (70A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 70A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
|
2814744SENSOR CURRENT HALL 55A AC/DC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (80A 10V)TRANSDUCER CURRENT 9-28VDC |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 80A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 2.8µs | - | -25°C ~ 70°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (80A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 80A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
2814650SENSOR CURRENT HALL 11A AC/DC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 11A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
![]() |
2814663SENSOR CURRENT HALL 55A AC/DC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 50mA | -20°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (100A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 100A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (20A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 20A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (90A 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 90A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (90A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 90A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |