Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ISOBLOCK I-ZF (300AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 300A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (50A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 50A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (300A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 300A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (200A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 200A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (150AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 150A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (10A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Obsolete | DC | Current Transducer | 10A | 1 | Open Collector | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (100AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 100A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
CR4320-30SENSOR CURRENT XFMR 30A AC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Active | AC | Transformer w/Conditioning | 30A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 24V | 200ms | - | -30°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
![]() |
1698172SENSOR CURRENT HALL 55A AC/DC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Active | AC/DC | Current Transducer | 50A | 1 | Analog Voltage | - | DC, 10Hz ~ 1kHz | - | - | 9.6V ~ 30V | 200ms | - | -40°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
![]() |
CR4320-50SENSOR CURRENT XFMR 50A AC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Active | AC | Transformer w/Conditioning | 50A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 24V | 200ms | - | -30°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
![]() |
CTR20000SENSOR CURRENT 100A, 150A, 200A |
0 |
|
![]() Datasheet |
CTR | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 100A, 150A, 200A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 10Hz ~ 400Hz | - | ±0.8% | 24V | 600ms | 23mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
CR4320-5SENSOR CURRENT XFMR 5A AC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Active | AC | Transformer w/Conditioning | 5A | 2 | Ratiometric, 4mA ~ 20mA | - | 50Hz/60Hz | - | ±0.5% | 24V | 200ms | - | -30°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HAZ 10000-SBSENSOR CURRENT HALL AC/DC 10000A |
0 |
|
![]() Datasheet |
- | Module | Bulk | Active | AC/DC | Hall Effect | 10000A | 1 | Analog Voltage | - | DC ~ 3kHz | ±0.5% | ±1% | 15V | - | 30mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
HOP 2000-SB/SP1SENSOR CURRENT HALL 2000A AC/DC |
0 |
|
![]() Datasheet |
- | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 2000A | 1 | Analog Voltage | - | DC ~ 4kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
CRD5150-XXX-XX-MCRD5150-XXX-XX-M |
0 |
|
![]() Datasheet |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
AKR 2000 C420L JTRANSDUCER |
0 |
|
- |
AKR | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 2000A | 1 | Analog Voltage | - | 10Hz ~ 400Hz | - | ±1% | 24V | 600ms | - | -20°C ~ 50°C | - | - | - | Chassis Mount | - |
![]() |
CTL0052SSENSOR CURRENT XFMR 2A, 5A AC |
0 |
|
![]() Datasheet |
CTL | Module, Single Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 2A, 5A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 100Hz | - | ±0.5% | 24V | 300ms | 40mA | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LV 100-2000/SP11SENSORS |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
CR4160-0.5SENSOR CURRENT XFMR 0.5A AC |
0 |
|
![]() Datasheet |
CR4100 | Module, Dual Pass Through | Bulk | Active | AC | Transformer w/Conditioning | 500mA | 2 | Ratiometric, 4mA ~ 20mA | - | 20Hz ~ 5kHz | - | ±0.5% | 24V | 250ms | 70mA | 0°C ~ 60°C | - | - | Bidirectional | DIN Rail, Panel | - |
![]() |
2814647SENSOR CURRENT HALL 55A AC/DC |
0 |
|
![]() Datasheet |
- | Module | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 55A | 1 | Ratiometric, Voltage and Current | - | 15Hz ~ 400Hz | - | ±0.5% | 20V ~ 30V | 330ms (AC), 40ms (DC) | 40mA | -20°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |