Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Terminal Type | Number of Turrets | Length - Above Board | Length - Below Flange | Length - Overall | Mounting Type | Termination | Flange Diameter | Diameter - Turret Head | Staking Side OD | Staking Side ID | Mounting Hole Diameter | Board Thickness | Contact Material | Contact Finish | Contact Finish Thickness | Insulation |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
2801-5-00-01-00-00-07-0TERM TURRET SINGLE L=9.14MM |
0 |
|
![]() Datasheet |
2801 | Bulk | Active | Single End | Single | 0.360" (9.14mm) | 0.234" (5.94mm) | 0.594" (15.09mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.145" (3.68mm) | 0.112" (2.84mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.188" (4.78mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2801-5-00-50-00-00-07-0TERM TURRET SINGLE L=9.14MM |
0 |
|
![]() Datasheet |
2801 | Bulk | Active | Single End | Single | 0.360" (9.14mm) | 0.234" (5.94mm) | 0.594" (15.09mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.145" (3.68mm) | 0.112" (2.84mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.188" (4.78mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2801-5-00-80-00-00-07-0TERM TURRET SNG |
0 |
|
![]() Datasheet |
2801 | Bulk | Active | Single End | Single | 0.360" (9.14mm) | 0.234" (5.94mm) | 0.594" (15.09mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.145" (3.68mm) | 0.112" (2.84mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.188" (4.78mm) | Brass Alloy | Tin | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2810-2-00-01-00-00-07-0TERM TURRET DOUBLE L=9.14MM |
0 |
|
![]() Datasheet |
2810 | Bulk | Active | Double End | Single, Double | 0.360" (9.14mm) | 0.181" (4.60mm) | 0.541" (13.74mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.082" (2.08mm), 0.145" (3.68mm) | - | - | 0.118" (3.00mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2810-2-00-50-00-00-07-0TERM TURRET DOUBLE L=9.14MM |
0 |
|
![]() Datasheet |
2810 | Bulk | Active | Double End | Single, Double | 0.360" (9.14mm) | 0.181" (4.60mm) | 0.541" (13.74mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.082" (2.08mm), 0.145" (3.68mm) | - | - | 0.118" (3.00mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2810-2-00-80-00-00-07-0TERM TURRET DBL |
0 |
|
![]() Datasheet |
2810 | Bulk | Active | Double End | Single, Double | 0.360" (9.14mm) | 0.181" (4.60mm) | 0.541" (13.74mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.082" (2.08mm), 0.145" (3.68mm) | - | - | 0.118" (3.00mm) | 0.062" (1.57mm) | Brass Alloy | Tin | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2806-2-00-01-00-00-07-0TERM TURRET SINGLE L=12.29MM |
0 |
|
![]() Datasheet |
2806 | Bulk | Active | Single End | Triple | 0.484" (12.29mm) | 0.109" (2.77mm) | 0.593" (15.06mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.144" (3.66mm), 0.145" (3.68mm) | 0.110" (2.79mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2806-2-00-50-00-00-07-0TERM TURRET SINGLE L=12.29MM |
0 |
|
![]() Datasheet |
2806 | Bulk | Active | Single End | Triple | 0.484" (12.29mm) | 0.109" (2.77mm) | 0.593" (15.06mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.144" (3.66mm), 0.145" (3.68mm) | 0.110" (2.79mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2806-2-00-80-00-00-07-0TERM TURRET SNG |
0 |
|
![]() Datasheet |
2806 | Bulk | Active | Single End | Triple | 0.484" (12.29mm) | 0.109" (2.77mm) | 0.593" (15.06mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.144" (3.66mm), 0.145" (3.68mm) | 0.110" (2.79mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.062" (1.57mm) | Brass Alloy | Tin | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2806-3-00-01-00-00-07-0TERM TURRET SINGLE L=12.29MM |
0 |
|
![]() Datasheet |
2806 | Bulk | Active | Single End | Triple | 0.484" (12.29mm) | 0.141" (3.58mm) | 0.625" (15.88mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.144" (3.66mm), 0.145" (3.68mm) | 0.110" (2.79mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.094" (2.39mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2806-3-00-50-00-00-07-0TERM TURRET SINGLE L=12.29MM |
0 |
|
![]() Datasheet |
2806 | Bulk | Active | Single End | Triple | 0.484" (12.29mm) | 0.141" (3.58mm) | 0.625" (15.88mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.144" (3.66mm), 0.145" (3.68mm) | 0.110" (2.79mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.094" (2.39mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2806-3-00-80-00-00-07-0TERM TURRET SNG |
0 |
|
![]() Datasheet |
2806 | Bulk | Active | Single End | Triple | 0.484" (12.29mm) | 0.141" (3.58mm) | 0.625" (15.88mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.144" (3.66mm), 0.145" (3.68mm) | 0.110" (2.79mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.094" (2.39mm) | Brass Alloy | Tin | 200.0µin (5.08µm) | Non-Insulated |
![]() |
1096-3-05-21-00-00-01-0TERM TURRET PIN L=3.33MM GOLD |
0 |
|
![]() Datasheet |
1096 | Bulk | Active | Double End, Pin | Single | 0.131" (3.33mm) | 0.662" (16.81mm) | 0.793" (20.14mm) | Through Hole | Press-Fit, Barbed, Wire Wrap | 0.072" (1.83mm) | 0.058" (1.47mm) | - | - | 0.057" (1.45mm) | - | Brass Alloy | Gold | 20.0µin (0.51µm) | Non-Insulated |
![]() |
2801-1-00-44-00-00-07-0TERM TURRET SINGLE L=9.14MM |
0 |
|
![]() Datasheet |
2801 | Bulk | Active | Single End | Single | 0.360" (9.14mm) | 0.078" (1.98mm) | 0.438" (11.13mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.145" (3.68mm) | 0.112" (2.84mm) | 0.078" (1.98mm) | 0.116" (2.95mm) | 0.031" (0.79mm) | Brass Alloy | Silver | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2803-3-00-44-00-00-07-0TERM TURRET SINGLE L=4.75MM |
0 |
|
![]() Datasheet |
2803 | Bulk | Active | Single End | Single | 0.187" (4.75mm) | 0.140" (3.56mm) | 0.327" (8.31mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.140" (3.56mm) | 0.110" (2.79mm) | 0.067" (1.70mm) | 0.113" (2.87mm) | 0.094" (2.39mm) | Brass Alloy | Silver | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2802-1-00-44-00-00-07-0TERM TURRET SINGLE L=7.92MM |
0 |
|
![]() Datasheet |
2802 | Bulk | Active | Single End | Double | 0.312" (7.92mm) | 0.078" (1.98mm) | 0.390" (9.91mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.150" (3.81mm) | 0.112" (2.84mm) | 0.078" (1.98mm) | 0.118" (3.00mm) | 0.031" (0.79mm) | Brass Alloy | Silver | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2802-2-00-44-00-00-07-0TERM TURRET SINGLE L=7.92MM |
0 |
|
![]() Datasheet |
2802 | Bulk | Active | Single End | Double | 0.312" (7.92mm) | 0.109" (2.77mm) | 0.421" (10.69mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.150" (3.81mm) | 0.112" (2.84mm) | 0.078" (1.98mm) | 0.118" (3.00mm) | 0.062" (1.57mm) | Brass Alloy | Silver | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2821-2-00-01-00-00-07-0TERM TURRET SINGLE L=10.72MM |
0 |
|
![]() Datasheet |
2821 | Bulk | Active | Single End | Double | 0.422" (10.72mm) | 0.109" (2.77mm) | 0.531" (13.50mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.152" (3.86mm) | 0.122" (3.10mm) | 0.089" (2.26mm) | 0.125" (3.18mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 200.0µin (5.08µm) | Non-Insulated |
![]() |
2821-2-00-50-00-00-07-0TERM TURRET SINGLE L=10.72MM |
0 |
|
![]() Datasheet |
2821 | Bulk | Active | Single End | Double | 0.422" (10.72mm) | 0.109" (2.77mm) | 0.531" (13.50mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.152" (3.86mm) | 0.122" (3.10mm) | 0.089" (2.26mm) | 0.125" (3.18mm) | 0.062" (1.57mm) | Brass Alloy | Tin-Lead | 300.0µin (7.62µm) | Non-Insulated |
![]() |
2821-2-00-80-00-00-07-0TERM TURRET SNG |
0 |
|
![]() Datasheet |
2821 | Bulk | Active | Single End | Double | 0.422" (10.72mm) | 0.109" (2.77mm) | 0.531" (13.50mm) | Through Hole | Swage | 0.187" (4.75mm) | 0.152" (3.86mm) | 0.122" (3.10mm) | 0.089" (2.26mm) | 0.125" (3.18mm) | 0.062" (1.57mm) | Brass Alloy | Tin | 200.0µin (5.08µm) | Non-Insulated |