Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Type | Input Range (Current, Voltage) | Input Range (Additional) | Output Type | Output Range | Isolation | Features | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RN42-AA1AUACTIVE BARRIER SCREW BOTTOM Endress+Hauser |
3 |
|
![]() Datasheet |
RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RN22-8L1BACTIVE BARRIER ATEX 1-CHANNEL Endress+Hauser |
4 |
|
![]() Datasheet |
RN22 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RN22-CB1B+LTACTIVE BARRIER CSA 1-CHANNEL Endress+Hauser |
2 |
|
![]() Datasheet |
RN22 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RN22-AA2A+LTACTIVE BARRIER 2-CHANNEL SCREW Endress+Hauser |
2 |
|
![]() Datasheet |
RN22 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RLN22-AA1AISOLATION AMPLIFIER, 1-CHANNEL Endress+Hauser |
2 |
|
![]() Datasheet |
RLN22 | Box | Active | Isolation Amplifier | - | - | - | - | - | 375V | Alarm Relay | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RLN22-8M2A+LAISOLATION AMPLIFIER, 2-CHANNEL Endress+Hauser |
2 |
|
![]() Datasheet |
RLN22 | Box | Active | Isolation Amplifier | - | - | - | - | - | 375V | Alarm Relay | 24V | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RN42-AA1AOACTIVE BARRIER SCREW TOP Endress+Hauser |
3 |
|
![]() Datasheet |
RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RN42-AA1BUACTIVE BARRIER PUSH-IN BOTTOM Endress+Hauser |
3 |
|
![]() Datasheet |
RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C |
![]() |
RLN42-8M2B+LAISOLATION AMPLIFIER, 2-CHANNEL Endress+Hauser |
2 |
|
![]() Datasheet |
RLN42 | Box | Active | Isolation Amplifier | - | - | - | - | - | 375V | - | 19.2 ~ 253VAC/VDC | DIN Rail | - | -40°C ~ 60°C |
![]() |
RN42-CB1AOACTIVE BARRIER SCREW TOP CSA Endress+Hauser |
3 |
|
![]() Datasheet |
RN42 | Box | Active | Signal Conditioner | Current | 0 ~ 20mA (Configurable) | - | Current | 0 ~ 20mA (Configurable) | 3000VAC (Test) | - | 24 ~ 230VAC/VDC | DIN Rail | Screw Terminal | -40°C ~ 60°C |