Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Grade | Qualification | Mounting Type | Supplier Device Package | Control Features | Approval Agency | Standard Number |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
07CR-18S08LGDC DC CONVERTER 8V 140W Bel Fuse Inc. |
0 |
|
![]() Datasheet |
07CR Cimarron (140W) | 5-DIP Module, 1/8 Brick | Tray | Obsolete | Isolated Module | 1 | 36V | 60V | 8V | - | - | - | 18A | 140 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, UVLO | -40°C ~ 85°C | 95% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
0RQB-C5T05LGDC DC CONVERTER 5V 150W Bel Fuse Inc. |
0 |
|
- |
0RQB-C5T | 8-DIP Module, 1/4 Brick | Tray | Not For New Designs | Isolated Module | 1 | 36V | 75V | 5V | - | - | - | 30A | 150 W | 2 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 92.5% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
0RQB-C0U03LGDC DC CONVERTER 3.3V 83W Bel Fuse Inc. |
0 |
|
- |
0RQB-C0U | 8-DIP Module, 1/4 Brick | Tray | Obsolete | Isolated Module | 1 | 18V | 75V | 3.3V | - | - | - | 25A | 83 W | 2 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 90% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
0RQB-50Y15LGDC-DC 24-110V IN 15V 3.3A OUT 50 Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-50Y15x (50W) | Quarter Brick | Tray | Active | Isolated Module, Conformal Coated | 1 | 14.4V | 154V | 15V | - | - | - | 3.3A | 50 W | 3 kV | ITE (Commercial) | Baseplate, Remote On/Off | -40°C ~ 105°C (With Derating) | 90% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CSA, UL | 62368-1 |
|
0RQB-50Y120GDC-DC 24-110V IN 12V 4.2A OUT 50 Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-50Y12x (50W) | Quarter Brick | Tray | Active | Isolated Module, Conformal Coated | 1 | 14.4V | 154V | 12V | - | - | - | 4.2A | 50 W | 3 kV | ITE (Commercial) | Baseplate, Remote On/Off | -40°C ~ 105°C (With Derating) | 91% | - | - | Through Hole | Quarter Brick | Enable, Active High | CSA, UL | 62368-1 |
|
0RQB-50Y050GDC-DC 24-110V IN 5V 10A OUT 50W Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-50Y05x (50W) | Quarter Brick | Tray | Active | Isolated Module, Conformal Coated | 1 | 14.4V | 154V | 5V | - | - | - | 10A | 50 W | 3 kV | ITE (Commercial) | Baseplate, Remote On/Off | -40°C ~ 105°C (With Derating) | 88% | - | - | Through Hole | Quarter Brick | Enable, Active High | CSA, UL | 62368-1 |
![]() |
0RQB-50Y48LGDC-DC 24-110V IN 48V 1A OUT 50W Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-50Y48x (50W) | Quarter Brick | Tray | Active | Isolated Module, Conformal Coated | 1 | 14.4V | 154V | 48V | - | - | - | 1.04A | 50 W | 3 kV | ITE (Commercial) | Baseplate, Remote On/Off | -40°C ~ 105°C (With Derating) | 88% | - | - | Through Hole | Quarter Brick | Enable, Active Low | CSA, UL | 62368-1 |
![]() |
0RQB-50Y240GDC-DC 24-110V IN 24V 2.1A OUT 50 Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-50Y24x (50W) | Quarter Brick | Tray | Active | Isolated Module, Conformal Coated | 1 | 14.4V | 154V | 24V | - | - | - | 2.1A | 50 W | 3 kV | ITE (Commercial) | Baseplate, Remote On/Off | -40°C ~ 105°C (With Derating) | 88% | - | - | Through Hole | Quarter Brick | Enable, Active High | CSA, UL | 62368-1 |
![]() |
0RQB-C0U12LGDC DC CONVERTER 12V 100W Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-C0U | 8-DIP Module, 1/4 Brick | Tray | Active | Isolated Module | 1 | 18V | 75V | 12V | - | - | - | 8.35A | 100 W | 2 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 91% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
0RQB-C5W54LGDC DC CONVERTER 54V 162W Bel Fuse Inc. |
0 |
|
![]() Datasheet |
0RQB-C5W54L (162W) | Quarter Brick | Box | Active | Isolated Module | 1 | 43V | 154V | 54V | - | - | - | 3A | 162 W | 2.25 kV | ITE (Commercial), Railway | Baseplate, Remote On/Off | -40°C ~ 95°C (With Derating) | 91% | - | - | Through Hole | Quarter Brick | Enable, Active Low | - | 62368-1 |