Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Input Range | Output | Isolation | Response Time | Accuracy | Voltage - Supply | Mounting Type | Termination Style | Operating Temperature | Approval Agency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ISOBLOCK V-4C (300V 10V)TRANSDUCER VOLTAGE 9-28VDC |
12 |
|
![]() Datasheet |
IsoBlock V | Box | Active | Voltage Transducer | ±300V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ISOBLOCK V-4C (500V 10V)TRANSDUCER VOLTAGE 9-28VDC |
10 |
|
![]() Datasheet |
IsoBlock V | Box | Active | Voltage Transducer | ±500V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ISOBLOCK V-4C (100V 10V)TRANSDUCER VOLTAGE 9-28VDC |
5 |
|
![]() Datasheet |
IsoBlock V | Box | Active | Voltage Transducer | ±100V | ±10V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
CR4620-150TRANSDUCER VOLTAGE 24VDC |
10 |
|
![]() Datasheet |
CR4600 | Box | Active | Average RMS AC Voltage Transducer | 0 ~ 150VAC | 4 ~ 20mA | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
|
CR4510-150TRANSDUCER VOLTAGE 24VDC |
4 |
|
![]() Datasheet |
CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 150VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
![]() |
ISOBLOCK I-FG-1C (15A 10V)TRANSDUCER CURRENT 9-28VDC |
15 |
|
![]() Datasheet |
IsoBlock I-FG | Box | Active | Current Transducer | 0 ~ 15A | ±10V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ISOBLOCK I-FG-1C (25A 10V)TRANSDUCER CURRENT 9-28VDC |
15 |
|
![]() Datasheet |
IsoBlock I-FG | Box | Active | Current Transducer | 0 ~ 25A | ±10V | 1200V (Working) | 5µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
|
2810612TRANSDUCER CURRENT 24VDC |
3 |
|
![]() Datasheet |
MCR | Bulk | Active | Current Transducer | 0 ~ 5A | 0 ~ 20mA | 4000VAC (Test) | - | - | 24VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C | ATEX, cULus |
![]() |
2308043TRANSDUCER CURRENT 24VDC |
2 |
|
![]() Datasheet |
MCR | Bulk | Active | Current Transducer | 0 ~ 300A | 4 ~ 20mA | 300VAC (Working), 3500VAC (Test) | 150ms | - | 24VDC | Chassis Mount, DIN Rail | Spring Terminal | -40°C ~ 65°C | CE, cULus |
|
2813486TRANSDUCER CURRENT 20-30VDC |
6 |
|
![]() Datasheet |
MCR | Bulk | Active | Current Transducer | 0 ~ 100A | 4 ~ 20mA | 5000VAC (Test) | 340ms | - | 20 ~ 30VDC | DIN Rail | Screw Terminal | -20°C ~ 60°C | CE, cULus |
![]() |
2810625TRANSDUCER CURR 19.2-253VAC/DC |
5 |
|
![]() Datasheet |
MCR | Bulk | Active | Current Transducer | 0 ~ 5A | 0 ~ 20mA | 4000VAC (Test) | 200ms | - | 19.2 ~ 253VAC/DC | DIN Rail | Screw Terminal | -20°C ~ 65°C | ATEX, cULus |
![]() |
2308085TRANSDUCER CURRENT 24VDC |
2 |
|
![]() Datasheet |
MCR | Bulk | Active | Current Transducer | 0 ~ 500A | 4 ~ 20mA | 300VAC (Working), 3500VAC (Test) | 150ms | - | 24VDC | DIN Rail | Spring Terminal | -40°C ~ 65°C | CE, cULus |
![]() |
ISOBLOCK V-1C (1000V 5V)TRANSDUCER VOLTAGE 9-28VDC |
15 |
|
![]() Datasheet |
IsoBlock V | Box | Active | Voltage Transducer | ±1000V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
ISOBLOCK V-1C (500V 5V)TRANSDUCER VOLTAGE 9-28VDC |
2 |
|
![]() Datasheet |
IsoBlock V | Box | Active | Voltage Transducer | ±500V | ±5V | 1500V (Working) | 2.8µs | ±0.2% | 9 ~ 28VDC | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |
![]() |
TCSA10TRANSDUCER CURRENT 10-30VDC |
3 |
|
![]() Datasheet |
TCSA | Bulk | Active | Current Transducer | 0 ~ 10A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250" (6.3mm) | -30°C ~ 60°C | CE, CSA, UL |
![]() |
TCSA5TRANSDUCER CURRENT 10-30VDC |
2 |
|
![]() Datasheet |
TCSA | Bulk | Active | Current Transducer | 0 ~ 5A | 4 ~ 20mA | - | 300ms | ±0.25% | 10 ~ 30VDC | Chassis Mount | Quick Connect - 0.250" (6.3mm) | -30°C ~ 60°C | CE, CSA, UL |
![]() |
DCSA50TRANSDUCER CURRENT 10-30VDC |
4 |
|
![]() Datasheet |
DCSA | Bulk | Active | Current Transducer | 0 ~ 50mA | 4 ~ 20mA, 1 ~ 10VDC | Not Isolated | 300ms | ±0.25% | 10 ~ 30VDC | DIN Rail | Screw Terminal | -30°C ~ 60°C | CE, CSA, UL |
|
E83-2050TRANSDUCER CURRENT 10-40VDC |
7 |
|
![]() Datasheet |
E83 | Bag | Active | Current Transducer | 0 ~ 50A | 4 ~ 20mA | - | 200ms | ±2% | 10 ~ 40VDC | DIN Rail | Screw Terminal | -20°C ~ 50°C | CE, UL |
|
CR4510-50TRANSDUCER VOLTAGE 24VDC |
7 |
|
![]() Datasheet |
CR4500 | Bulk | Active | True RMS AC Voltage Transducer | 0 ~ 50VAC | 0 ~ 5VDC | 2500VDC | 250ms | 0.5% | 24VDC | DIN Rail | Screw Terminal | 0°C ~ 60°C | CE, cURus |
![]() |
ENTUBE SE (1500V 10V)TRANSDUCER VOLTAGE DIVIDER |
3 |
|
![]() Datasheet |
Entube SE | Box | Active | Voltage Transducer | ±1500V | ±10V | - | - | ±0.2% | - | DIN Rail | Spring Terminal | -25°C ~ 70°C | - |