Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Sensor Type | Humidity Range | Output Type | Output | Accuracy | Response Time | Sensitivity | Voltage - Supply | Mounting Type | Operating Temperature | Grade | Qualification | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
A/RH3-1K-NI-ORelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
![]() Datasheet |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-1K-NI-SP-05Relative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 5V | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH3-100-2W-ORelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-100KS-ORelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-CSI-O-BBRelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-CSI-ORelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-BALCO-ORelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-3K-ORelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-CP-O-BBRelative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-CP-R2SO-A04-C5Relative Humidity, RH Outputs: 0 Automation Components, Inc. |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |