Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ISOBLOCK I-ZF (2000AAC 7VAC )ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Ratiometric, Voltage | - | 50kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (2000A 10V)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (1500A 10V)VOLTAGE TRANSDUCER W/ISOLATION |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (1500A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (2000A 5V)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.1% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
CD 1000-T/SP7TRANSDUCER |
0 |
|
- |
CD | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate | 10A | 1 | Current | - | DC ~ 20kHz | - | - | ±24V | - | - | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
GT1218GROUND FAULT SENSOR CURRENT TRAN |
0 |
|
![]() Datasheet |
- | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
ISOBLOCK I-ZF (1500A 10V 0.02%)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (2000A 10V 0.02%)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (1500A 5V 0.02%)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 1500A | 1 | Open Collector | - | 60kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (2000A 5V 0.02%)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Open Collector | - | 50kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
ISOBLOCK I-ZF (2000AAC 7VAC 0.02%)ZERO FLUX CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ZF | Module | Box | Active | DC | Current Transducer | 2000A | 1 | Ratiometric, Voltage | - | 50kHz | ±0.02% | ±0.2% | 24VDC | 1µs | - | -25°C ~ 70°C | - | - | Unidirectional | DIN Rail | - |
![]() |
LT 10000-STRANSDUCER |
0 |
|
- |
LT | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 10000A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±48V ~ 60V | 1µs | 40mA | -25°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
DL2000UB-10VCURRENT TRANSDUCER 2000A |
0 |
|
- |
DL | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 2000A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.002% | - | ±14.25V ~ 15.75V | 1µs | 190mA | -40°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
3-1616987-3HECS6001=HALL EFFECT CURRENT SEN |
0 |
|
- |
- | Module | Bulk | Active | DC | Hall Effect | 600A | 1 | Voltage | 6.67mV/A | - | - | - | 16V ~ 32V | - | 35mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
![]() |
8-1616988-7HECS6004=HALL EFFECT CURRENT SEN |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
3-2252001-3E145S1=OVERCURRENT SENSING CONTA |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
3-2252001-4E145P1=OVERCURRENT SENSING CONTA |
0 |
|
- |
- | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LTS 6-NPSENSOR CURRENT HALL 6A AC/DC |
0 |
|
![]() Datasheet |
LTS | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
![]() |
LTS 15-NPSENSOR CURRENT HALL 15A AC/DC |
0 |
|
![]() Datasheet |
LTS | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.6mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 5V | 0.4µs | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |