Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
ISOBLOCK I-ST-1C (1MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 1mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (500MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 500mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (2MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 2mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (20MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 20mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (5MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 5mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (4MA 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 4mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (200MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 200mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (10A 5V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 10A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (4MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 4mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (10MA 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 10mA | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
ISOBLOCK I-ST-1C (3A 10V)SHUNT BASED CURRENT SENSOR |
0 |
|
![]() Datasheet |
IsoBlock I-ST | Module | Box | Active | - | Current Transducer | 3A | 1 | Open Collector | - | - | - | ±0.2% | 9V ~ 28VDC | 5µs | - | -25°C ~ 65°C | - | - | - | DIN Rail | - |
![]() |
LF 2005-S/SP28TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.5% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LF 2005-S/SP23TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LF 2005-S/SP34TRANSDUCER |
0 |
|
- |
LF | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Current | - | DC ~ 100kHz | ±0.1% | ±0.3% | ±15V ~ 24V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LT 505-T/SP20TRANSDUCER |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
LT 505-T/SP12TRANSDUCER |
0 |
|
- |
LT | Module | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 800A | 1 | Current | - | DC ~ 150kHz | ±0.1% | ±0.5% | ±15V | 1µs | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
PCM 30-P/SP2TRANSDUCER |
0 |
|
- |
PCM | Module, Single Pass Through | Bulk | Not For New Designs | DC | Hall Effect, Closed Loop | 30A | 1 | Current | - | DC ~ 1kHz | ±0.2% | ±1% | ±24V | 30µs | 65mA | -25°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
![]() |
LV 100-3000/SP11SENSORS |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
![]() |
789-622CURRENT SIGNAL CONDITIONER; CURR |
0 |
|
![]() Datasheet |
- | Module | Box | Active | DC | Current Sensor | 50A | 1 | - | - | - | - | - | 24V | - | - | -20°C ~ 70°C | - | - | - | DIN Rail | - |
![]() |
LV 100-150/SP4SENSORS |
0 |
|
- |
- | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |