Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
GV2ME10TESYS M-CB THO/MAG 4-6.3A ROCKER Schneider Electric |
2 |
|
- |
TeSys | Box | Active | DIN Rail | Thermal Magnetic | 6.3A | 690 V | 690 V | Pushbutton | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
![]() |
GV2P08TESYS MOTOR CIRCUIT BREAKER Schneider Electric |
5 |
|
![]() Datasheet |
TeSys | Box | Active | DIN Rail | Thermal Magnetic | 4A | 690 V | 690 V | Rotary | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
![]() |
GV2P07TESYS MOTOR CIRCUIT BREAKER Schneider Electric |
4 |
|
![]() Datasheet |
TeSys | Box | Active | DIN Rail | Thermal Magnetic | 2.5A | 690 V | 690 V | Rotary | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
![]() |
GV2P06TESYS MOTOR CIRCUIT BREAKER Schneider Electric |
2 |
|
![]() Datasheet |
TeSys | Box | Active | DIN Rail | Thermal Magnetic | 1.6A | 690 V | - | Rotary | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
![]() |
GV2P16TESYS MOTOR CIRCUIT BREAKER Schneider Electric |
3 |
|
![]() Datasheet |
TeSys | Box | Active | Chassis Mount | Thermal Magnetic | 14A | 690 V | - | Rotary | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
![]() |
GV2P20TESYS MOTOR CIRCUIT BREAKER Schneider Electric |
2 |
|
- |
TeSys | Box | Active | Panel Mount | Thermal Magnetic | 18A | 690 V | 690 V | Rotary | 3 | None | - | EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1 |
![]() |
GV3P65TESYS 3P MOTOR CB THO/MAG 48-65A Schneider Electric |
2 |
|
- |
TeSys | Box | Active | DIN Rail | Thermal Magnetic | 65A | 690 V | - | Rotary | 3 | None | - | CSA C22.2 No 60947-4-1, EN 60947-2, EN 60947-4-1, IEC 60947-2, IEC 60947-4-1, UL60947-4-1 |
![]() |
BDL26030MOLDED CASE CIRCUIT BRKR 600Y/34 Schneider Electric |
5 |
|
- |
PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 30A | 600 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
![]() |
BDL26020MOLDED CASE CIRCUIT BRKR 600Y/34 Schneider Electric |
5 |
|
- |
PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 20A | 600 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |
![]() |
BDL26015MOLDED CASE CIRCUIT BRKR 600Y/34 Schneider Electric |
5 |
|
- |
PowerPact | Box | Active | DIN Rail | Thermal Magnetic | 15A | 600 V | - | Toggle | 2 | None | - | CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489 |