Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Frame Type | Loading Side | Cavity Height | Cavity Width | Minimum Bend Radius | Outer Height | Outer Width | Length | Link Pitch | Features | Material | Operating Temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
E08-40-038-0CABLE CARRIER .76H X 1.90W 1=1FT |
172 |
|
![]() Datasheet |
E08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.570" (39.88mm) | 1.500" (38.10mm) | 0.760" (19.30mm) | 1.900" (48.26mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-2-028-0CABLE CARRIER .98H X 1.46W 1=1FT |
293 |
|
![]() Datasheet |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.980" (24.89mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.460" (37.08mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-2-038-0CABLE CARRIER .98H X 1.46W 1=1FT |
200 |
|
![]() Datasheet |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.980" (24.89mm) | 1.500" (38.10mm) | 0.980" (24.89mm) | 1.460" (37.08mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z14-2-048-0CABLE CARRIER .98H X 1.46W 1=1FT |
186 |
|
![]() Datasheet |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.980" (24.89mm) | 1.890" (48.01mm) | 0.980" (24.89mm) | 1.460" (37.08mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z14-2-038-0CABLE CARRIER .98H X 1.46W 1=1FT |
184 |
|
![]() Datasheet |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.980" (24.89mm) | 1.500" (38.10mm) | 0.980" (24.89mm) | 1.460" (37.08mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-2-048-0CABLE CARRIER .98H X 1.46W 1=1FT |
171 |
|
![]() Datasheet |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.980" (24.89mm) | 1.890" (48.01mm) | 0.980" (24.89mm) | 1.460" (37.08mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z14-2-028-0CABLE CARRIER .98H X 1.46W 1=1FT |
146 |
|
![]() Datasheet |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 0.980" (24.89mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.460" (37.08mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E2-10-30-038-0CABLE CARRIER .59H X 1.47W 1=1FT |
198 |
|
![]() Datasheet |
E2-10 | Bulk | Active | Open | Inside and Outside Bend | 0.420" (10.67mm) | 1.180" (29.97mm) | 1.500" (38.10mm) | 0.590" (14.99mm) | 1.470" (37.34mm) | 12.000" (304.80mm) | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-10-30-028-0CABLE CARRIER .59H X 1.47W 1=1FT |
197 |
|
![]() Datasheet |
E2I-10 | Bulk | Active | Open | Inside and Outside Bend | 0.400" (10.16mm) | 1.180" (29.97mm) | 1.100" (27.94mm) | 0.590" (14.99mm) | 1.470" (37.34mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-10-30-038-0CABLE CARRIER .59H X 1.47W 1=1FT |
195 |
|
![]() Datasheet |
E2I-10 | Bulk | Active | Open | Inside and Outside Bend | 0.400" (10.16mm) | 1.180" (29.97mm) | 1.500" (38.10mm) | 0.590" (14.99mm) | 1.470" (37.34mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2I-10-30-018-0CABLE CARRIER .59H X 1.47W 1=1FT |
179 |
|
![]() Datasheet |
E2I-10 | Bulk | Active | Open | Inside and Outside Bend | 0.400" (10.16mm) | 1.180" (29.97mm) | 0.710" (18.03mm) | 0.590" (14.99mm) | 1.470" (37.34mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E2-10-30-028-0CABLE CARRIER .59H X 1.47W 1=1FT |
175 |
|
![]() Datasheet |
E2-10 | Bulk | Active | Open | Inside and Outside Bend | 0.420" (10.67mm) | 1.180" (29.97mm) | 1.100" (27.94mm) | 0.590" (14.99mm) | 1.470" (37.34mm) | 12.000" (304.80mm) | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
14-3-028-0CABLE CARRIER .98H X 1.93W 1=1FT |
174 |
|
![]() Datasheet |
14 | Bulk | Active | Open | Inside and Outside Bend | 0.790" (20.07mm) | 1.500" (38.10mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.930" (49.02mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 120°C |
![]() |
E08-50-038-0CABLE CARRIER .76H X 2.29W 1=1FT |
195 |
|
![]() Datasheet |
E08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.970" (50.04mm) | 1.500" (38.10mm) | 0.760" (19.30mm) | 2.290" (58.17mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E08-50-048-0CABLE CARRIER .76H X 2.29W 1=1FT |
195 |
|
![]() Datasheet |
E08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.970" (50.04mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 2.290" (58.17mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z08-50-048-0CABLE CARRIER .76H X 2.29W 1=1FT |
191 |
|
![]() Datasheet |
Z08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.970" (50.04mm) | 1.890" (48.01mm) | 0.760" (19.30mm) | 2.290" (58.17mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z08-50-028-0CABLE CARRIER .76H X 2.29W 1=1FT |
190 |
|
![]() Datasheet |
Z08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.970" (50.04mm) | 1.100" (27.94mm) | 0.760" (19.30mm) | 2.290" (58.17mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z08-50-038-0CABLE CARRIER .76H X 2.29W 1=1FT |
175 |
|
![]() Datasheet |
Z08 | Bulk | Active | Open | Inside and Outside Bend | 0.570" (14.48mm) | 1.970" (50.04mm) | 1.500" (38.10mm) | 0.760" (19.30mm) | 2.290" (58.17mm) | - | 0.790" (20.07mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
Z14-3-028-0CABLE CARRIER .98H X 1.97W 1=1FT |
460 |
|
![]() Datasheet |
Z14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 1.500" (38.10mm) | 1.100" (27.94mm) | 0.980" (24.89mm) | 1.970" (50.04mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |
![]() |
E14-3-038-0CABLE CARRIER .98H X 1.97W 1=1FT |
195 |
|
![]() Datasheet |
E14 | Bulk | Active | Open | Inside and Outside Bend | 0.750" (19.05mm) | 1.500" (38.10mm) | 1.500" (38.10mm) | 0.980" (24.89mm) | 1.970" (50.04mm) | - | 1.200" (30.48mm) | - | Igumid G | -40°C ~ 80°C |