Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CX10S-DHHDDH-P-A-DK00000ACDC CNV 5V 24V 2X48V 5V 24V 5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 48V | 5V | 24V | 5V | 24V | 48V | 4.17 A | 6 A | 3 A | 6 A | 3 A | 4.17 A | 900W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-D0HGDD-P-A-DK00000AC/DC CNVT 2X48V 2X24V 48V 5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 48V | 5V | 24V | 24V | 24V | 48V | 4.17 A | 6 A | 3 A | 3 A | 3 A | 4.17 A | 820W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DHHDHB-P-A-DK00000AC/DC 12V 5V 24V 48V 5V 24V 5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 48V | 5V | 24V | 5V | 24V | 48V | 4.17 A | 6 A | 3 A | 6 A | 3 A | 4.17 A | 880W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGHHBB-P-A-DK00000ACDC CNVT 2X12V 5V 3X24V 5V 800W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 3 A | 3 A | 3 A | 3 A | 6 A | 3 A | 800W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGHHGA-P-A-DK00000ACDC CNVT 5V 2X24V 5V 3X24V 665W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 3 A | 3 A | 3 A | 3 A | 6 A | 3 A | 665W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HDCDCB-P-A-DK00000AC/DC CNVT 12V 24V 48V 24V 2X48V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 24V | 48V | 24V | 48V | 24V | 6 A | 3 A | 4.17 A | 8.3 A | 4.17 A | 8.3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DDBBGG-P-A-DK00000AC/DC CNVT 4X24V 48V 12V 1000W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 48V | 48V | 12V | 12V | 24V | 24V | 4.17 A | 4.17 A | 15 A | 15 A | 3 A | 3 A | 1000W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HHHGGG-P-A-DK00000AC/DC CNVT 4X24V 5V 2X24V 660W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 5V | 24V | 6 A | 3 A | 6 A | 3 A | 6 A | 3 A | 660W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GHHHGG-P-A-DK00000AC/DC CNVT 4X24V 5V 24V 5V 660W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 12 | 85 ~ 264 VAC | 24V | 24V | 5V | 24V | 5V | 24V | 3 A | 3 A | 6 A | 3 A | 6 A | 3 A | 660W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-AAACAH-P-A-DK00000AC/DC CNVT 5V 24V 5V 24V 2X5V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 7 | 85 ~ 264 VAC | 5V | 5V | 5V | 24V | 5V | 5V | 21 A | 21 A | 21 A | 8.3 A | 21 A | 6 A | 720W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-CGBBHH-P-A-DK00000AC/DC CNVT 5V 24V 5V 3X24V 12V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 24V | 12V | 12V | 5V | 8.3 A | 3 A | 3 A | 15 A | 15 A | 6 A | 880W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GCGCCG-P-A-DK00000AC/DC CONVERTER 6X24V 960W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 3 A | 3 A | 8.3 A | 3 A | 3 A | 8.3 A | 960W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DGGGGG-P-A-DK00000AC/DC CONVERTER 6X24V 24V 800W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 48V | 24V | 24V | 24V | 24V | 24V | 4.17 A | 3 A | 3 A | 3 A | 3 A | 3 A | 800W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HBHHHB-P-A-DK00000AC/DC CNVT 12V 5V 24V 5V 12V 24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 5V | 24V | 12V | 5V | 24V | 5V | 6 A | 3 A | 15 A | 6 A | 3 A | 6 A | 760W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGGBGB-P-A-DK00000AC/DC CNVT 12V 2X24V 12V 3X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 24V | 24V | 3 A | 3 A | 3 A | 3 A | 3 A | 3 A | 840W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GHCGBC-P-A-DK00000ACDC CNVT 24V 12V 2X24V 5V 2X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 5V | 24V | 24V | 24V | 3 A | 3 A | 6 A | 3 A | 8.3 A | 3 A | 920W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GGHHHD-P-A-DK00000AC/DC CNVT 48V 5V 24V 5V 3X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 11 | 85 ~ 264 VAC | 24V | 24V | 24V | 24V | 5V | 24V | 3 A | 3 A | 3 A | 3 A | 6 A | 3 A | 740W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-DGAGBB-P-A-DK00000AC/DC CNVT 2X12V 4X24V 5V 905W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 8 | 85 ~ 264 VAC | 48V | 24V | 24V | 5V | 24V | 24V | 4.17 A | 3 A | 3 A | 21 A | 3 A | 3 A | 905W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-HHGBBH-P-A-DK00000AC/DC CNVT 5V 24V 2X12V 5V 2X24V |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 10 | 85 ~ 264 VAC | 5V | 24V | 5V | 24V | 24V | 24V | 6 A | 3 A | 6 A | 3 A | 3 A | 3 A | 780W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |
![]() |
CX10S-GDGBGC-P-A-DK00000ACDC CNVT 3X24V 12V 48V 24V 940W |
0 |
|
![]() Datasheet |
COOLX®1000 | Box | Active | Enclosed | 9 | 85 ~ 264 VAC | 24V | 24V | 48V | 24V | 24V | 12V | 3 A | 3 A | 4.17 A | 3 A | 3 A | 15 A | 940W | ITE (Commercial), Medical | 4 kV | -40°C ~ 85°C | Adjustable Output, PMBus™, Remote Sense, Standby Output, Universal Input | Chassis Mount | 10.22" L x 6.46" W x 1.60" H (259.5mm x 164.0mm x 40.6mm) |