Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
PMMK320S-24EAC/DC CONVERTER 24V 322W Astrodyne TDI |
252 |
|
![]() Datasheet |
PMMK320E (320W) | Bulk | Active | Enclosed | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 13.4 A | - | - | - | - | - | 322W | Medical | 5.656 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Remote Sense, Universal Input | Chassis Mount | - |
![]() |
PMK150S-12AC/DC CONVERTER 12V 150W Astrodyne TDI |
31 |
|
![]() Datasheet |
PMK150 (150W) | Bulk | Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 150W | ITE (Commercial) | 4.242 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | - |
![]() |
PMK150S-5AC/DC CONVERTER 5V 150W Astrodyne TDI |
29 |
|
![]() Datasheet |
PMK150 (150W) | Bulk | Active | Open Frame | 1 | 90 ~ 264 VAC | 5V | - | - | - | - | - | 30 A | - | - | - | - | - | 150W | ITE (Commercial) | 4.242 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | - |
![]() |
PMK150S-24UAC/DC CONVERTER 24V 151W Astrodyne TDI |
61 |
|
![]() Datasheet |
PMK150U (151W) | Bulk | Active | Open Frame | 1 | 90 ~ 264 VAC | 24V | - | - | - | - | - | 6.3 A | - | - | - | - | - | 151W | ITE (Commercial) | 4.242 kV | -10°C ~ 70°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 5.50" L x 3.17" W x 1.60" H (139.7mm x 80.5mm x 40.6mm) |
![]() |
PMK150S-12EAC/DC CONVERTER 12V 150W Astrodyne TDI |
31 |
|
![]() Datasheet |
PMK150E (150W) | Bulk | Active | Enclosed | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 150W | ITE (Commercial), Medical | 4.242 kV | -10°C ~ 70°C | Universal Input | Chassis Mount | 5.05" L x 3.17" W x 1.60" H (128.3mm x 80.5mm x 40.6mm) |
![]() |
BSM400S-19AC/DC CONVERTER 19V 200W Astrodyne TDI |
1,003 |
|
![]() Datasheet |
BSM400S (400W) | Box | Active | Open Frame | 1 | 90 ~ 264 VAC | 19V | - | - | - | - | - | 10.5 A | - | - | - | - | - | 200W (401W Forced Air) | Medical | 4 kV | -20°C ~ 40°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) |
![]() |
ASM400S-48AC/DC CONVERTER 48V 250W Astrodyne TDI |
617 |
|
![]() Datasheet |
ASM400S (400W) | Box | Active | Open Frame | 1 | 90 ~ 264 VAC | 48V | - | - | - | - | - | 5.2 A | - | - | - | - | - | 250W (398W Forced Air) | Medical | 4 kV | -20°C ~ 40°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) |
![]() |
ASM400S-28AC/DC CONVERTER 28V 199W Astrodyne TDI |
396 |
|
![]() Datasheet |
ASM400S (400W) | Box | Active | Open Frame | 1 | 90 ~ 264 VAC | 28V | - | - | - | - | - | 7.1 A | - | - | - | - | - | 199W (400W Forced Air) | Medical | 4 kV | -20°C ~ 40°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) |
![]() |
ASM400S-15AC/DC CONVERTER 15V 200W Astrodyne TDI |
83 |
|
![]() Datasheet |
ASM400S (400W) | Box | Active | Open Frame | 1 | 90 ~ 264 VAC | 15V | - | - | - | - | - | 13.3 A | - | - | - | - | - | 200W (401W Forced Air) | Medical | 4 kV | -20°C ~ 40°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) |
![]() |
ASM400S-12AC/DC CONVERTER 12V 200W Astrodyne TDI |
58 |
|
![]() Datasheet |
ASM400S (400W) | Box | Active | Open Frame | 1 | 90 ~ 264 VAC | 12V | - | - | - | - | - | 16.7 A | - | - | - | - | - | 200W (400W Forced Air) | Medical | 4 kV | -20°C ~ 40°C (With Derating) | Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.32" H (127.0mm x 76.2mm x 33.5mm) |