Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CUS600M-28AC/DC CONVERTER 28V 400W TDK-Lambda |
61 |
|
![]() Datasheet |
CUS600M (600W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 28V | - | - | - | - | - | 14.3 A | - | - | - | - | - | 400W (602W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) |
![]() |
CUS600M-19AC/DC CONVERTER 19V 401W TDK-Lambda |
48 |
|
![]() Datasheet |
CUS600M (600W) | Box | Active | Open Frame | 1 | 85 ~ 265 VAC | 19V | - | - | - | - | - | 21.1 A | - | - | - | - | - | 401W (600W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.34" H (127.0mm x 76.2mm x 34.0mm) |
|
ZWQ130-5224AC/DC CNVRTR 5V +/-12V 24V 130W TDK-Lambda |
31 |
|
![]() Datasheet |
ZWQ (130W) | Bulk | Active | Open Frame | 4 | 85 ~ 265 VAC | 5V | 12V | -12V | 24V | - | - | 15 A | 4 A | 4 A | 2 A | - | - | 130W | ITE (Commercial) | 3 kV | -10°C ~ 60°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.86" L x 4.17" W x 1.38" H (225.0mm x 106.0mm x 35.0mm) |
|
RWS600B-24AC/DC CONVERTER 24V 600W TDK-Lambda |
627 |
|
![]() Datasheet |
RWS-B (600W) | Bulk | Active | Enclosed | 1 | 85 ~ 265 VAC | 24V | - | - | - | - | - | 25 A | - | - | - | - | - | 600W | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 7.48" L x 4.72" W x 2.40" H (190.0mm x 120.0mm x 61.0mm) |
|
RWS600B-48AC/DC CONVERTER 48V 600W TDK-Lambda |
216 |
|
![]() Datasheet |
RWS-B (600W) | Bulk | Active | Enclosed | 1 | 85 ~ 265 VAC | 48V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 600W | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Universal Input | Chassis Mount | 7.48" L x 4.72" W x 2.40" H (190.0mm x 120.0mm x 61.0mm) |
|
GWS250-12AC/DC CONVERTER 12V 250W TDK-Lambda |
56 |
|
![]() Datasheet |
GWS (250W) | Bulk | Active | Enclosed | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 21 A | - | - | - | - | - | 250W | ITE (Commercial) | 3 kV | -25°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 7.80" L x 4.10" W x 1.61" H (198.0mm x 104.0mm x 41.0mm) |
|
GWS250-48AC/DC CONVERTER 48V 250W TDK-Lambda |
55 |
|
![]() Datasheet |
GWS (250W) | Bulk | Active | Enclosed | 1 | 85 ~ 264 VAC | 48V | - | - | - | - | - | 5.3 A | - | - | - | - | - | 250W | ITE (Commercial) | 3 kV | -25°C ~ 70°C (With Derating) | Adjustable Output, DC Input Capable, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 7.80" L x 4.10" W x 1.61" H (198.0mm x 104.0mm x 41.0mm) |
|
ZWQ130-5224/AAC/DC CNVRTR 5V +/-12V 24V 130W TDK-Lambda |
36 |
|
![]() Datasheet |
ZWQ (130W) | Bulk | Active | Enclosed | 4 | 85 ~ 265 VAC | 5V | 12V | -12V | 24V | - | - | 15 A | 4 A | 4 A | 2 A | - | - | 130W | ITE (Commercial) | 3 kV | -10°C ~ 60°C (With Derating) | Adjustable Output, PFC, Universal Input | Chassis Mount | 8.86" L x 4.17" W x 1.38" H (225.0mm x 106.0mm x 35.0mm) |
![]() |
CUS600M-48/EFAC/DC CONVERTER 48V 403W TDK-Lambda |
33 |
|
![]() Datasheet |
CUS600M (600W) | Box | Active | Enclosed | 1 | 85 ~ 265 VAC | 48V | - | - | - | - | - | 8.4 A | - | - | - | - | - | 403W (605W Forced Air) | ITE (Commercial), Medical | 4 kV | -20°C ~ 70°C (With Derating) | Adjustable Output, Remote On/Off, Remote Sense, Standby Output, Universal Input | Chassis Mount | 6.18" L x 3.35" W x 1.67" H (157.0mm x 85.0mm x 42.5mm) |
|
NV1-4G5TTAC/DC CNVRTR 24V 5V +/-12V 180W TDK-Lambda |
61 |
|
![]() Datasheet |
NV175 (175-200W) | Bulk | Active | Open Frame | 4 | 90 ~ 264 VAC | 24V | 5V | 12V | -12V | - | - | 7.5 A | 10 A | 5 A | 1 A | - | - | 180W | ITE (Commercial), Medical | 4.3 kV | 0°C ~ 70°C (With Derating) | Adjustable Output, PFC, Remote Sense, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.25" H (127.0mm x 76.2mm x 31.8mm) |