Photo | Mfr. Part # | Availability | Quantity | Datasheet | Series | Packaging | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Current - Output 1 | Current - Output 2 | Current - Output 3 | Current - Output 4 | Current - Output 5 | Current - Output 6 | Power (Watts) | Applications | Voltage - Isolation | Operating Temperature | Features | Mounting Type | Size / Dimension |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
MPE-S20312V/12.5A 150W convection, 200W Magic Power |
50 |
|
![]() Datasheet |
MPE-S200 (200W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 16.6 A | - | - | - | - | - | 150W (199W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 80°C (With Derating) | Universal Input | Chassis Mount | 4.00" L x 2.00" W x 1.48" H (101.6mm x 50.8mm x 37.6mm) |
![]() |
MPE-G12312V 10A 120W convection, 150W wi Magic Power |
50 |
|
![]() Datasheet |
MPE-G120 (120W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC, 130 ~ 370 VDC | 12V | - | - | - | - | - | 12.5 A | - | - | - | - | - | 120W (150W Forced Air) | ITE (Commercial) | 3 kV | -20°C ~ 70°C (With Derating) | DC Input Capable, PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.14" W x 1.35" H (127.0mm x 76.2mm x 34.3mm) |
![]() |
MPM-S123-SB12V, 10A & 5Vsb 120W open frame Magic Power |
20 |
|
![]() Datasheet |
MPM-S120 (120W) | Bulk | Active | Open Frame | 2 | 85 ~ 264 VAC | 12V | 5V | - | - | - | - | 500 mA | 11.25 A | - | - | - | - | 123W (138W Forced Air) | Medical | 4 kV | -20°C ~ 70°C (With Derating) | Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.60" H (127.0mm x 76.2mm x 40.6mm) |
![]() |
MPM-K453-SB-112V/25A medical 300W convection, Magic Power |
13 |
|
![]() Datasheet |
MPM-K453 (450W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC | 12V | - | - | - | - | - | 37.5 A | - | - | - | - | - | 450W | ITE (Commercial), Medical | 4 kV | -30°C ~ 70°C (With Derating) | PFC, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 6.00" L x 4.00" W x 1.48" H (152.4mm x 101.6mm x 37.6mm) |
![]() |
MPI-G50524V/12.5A 300W convection, 500W Magic Power |
4 |
|
![]() Datasheet |
MPI-G505 (500W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 24V | - | - | - | - | - | 20.83 A | - | - | - | - | - | 300W (500W Forced Air) | Household Appliances, ITE (Commercial) | 3 kV | -20°C ~ 80°C (With Derating) | Adjustable Output, PFC, Remote On/Off, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.0mm) |
![]() |
MPI-G50312V/25A 300W convection, 500W wi Magic Power |
4 |
|
![]() Datasheet |
MPI-G503 (500W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 12V | - | - | - | - | - | 41.67 A | - | - | - | - | - | 300W (500W Forced Air) | Household Appliances, ITE (Commercial) | 3 kV | -20°C ~ 80°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.50" H (127.0mm x 76.2mm x 38.0mm) |
![]() |
MPI-822H-BATX PSU, 170W convection, 220W w Magic Power |
0 |
|
![]() Datasheet |
MPI-822H-B(220W) | Bulk | Active | Open Frame | 4 | 90 ~ 264 VAC | 5V | 12V | -12V | 3.3V | - | - | 1 A | 12 A | 12 A | 14 A | - | - | 146W (266W Forced Air) | ITE (Commercial) | 3 kV | -10°C ~ 80°C (With Derating) | Universal Input | Chassis Mount | 7.80" L x 3.82" W x 1.59" H (198.0mm x 97.0mm x 40.5mm) |
![]() |
MPI-G40524V 10.41A 250W convection, 400W Magic Power |
0 |
|
![]() Datasheet |
MPI-G400 (400W) | Bulk | Active | Open Frame | 1 | 80 ~ 264 VAC | 24V | - | - | - | - | - | 16.67 A | - | - | - | - | - | 250W (400W Forced Air) | Household Appliances, ITE (Commercial) | 3 kV | -20°C ~ 80°C | PFC, Standby Output, Universal Input | Chassis Mount | 5.00" L x 3.00" W x 1.46" H (127.0mm x 76.2mm x 37.1mm) |
![]() |
MPM-S05524V/2.08A medical 50W convection Magic Power |
5 |
|
![]() Datasheet |
MPM-S055 (50W) | Bulk | Active | Open Frame | 1 | 85 ~ 264 VAC | 24V | - | - | - | - | - | 2.5 A | - | - | - | - | - | 50W (60W Forced Air) | Medical | 4 kV | -20°C ~ 80°C (With Derating) | Adjustable Output, Universal Input | Chassis Mount | 3.00" L x 2.00" W x 1.01" H (76.2mm x 50.8mm x 25.6mm) |